W1218 DC 12V LED Digital Thermostat Temperature Controller Regulator Thermometer Monitor Red/Blue Display For Incubator

W1218 DC 12V LED Digital Thermostat Temperature Controller Regulator Thermometer Monitor Red/Blue Display For Incubator
Eachine1
sku: 1561127
ACCORDING TO OUR RECORDS THIS PRODUCT IS NOT AVAILABLE NOW
$4.34
Shipping from: China
   Description
Feature: Probe operating temperature: -20C - 100C Display operating temperature: -10C to 60C Operating voltage: 12V DC Measurement accuracy: 0.1C Control accuracy: 0.1C Return difference accuracy: 0.1C Refresh rate: 0.5s Measuring input: NTC (10K 0.5%) length 0.3meter,waterproof sensor Output: 1 way 10A /250VAC 20A/14VDC relay Humidity: 20% to 85% Power consumption: 35mA (static) 65mA (relay close) Module size: 47 x 40 mm PROGRAMMING: 1. Press the SET button on the display flashes the temperature that can be changed with the + and - keys. 2. Press and hold the SET button for a few seconds. 0P0 will appear on the display Program responsible for heating "H" or cooling "C" If 0P0 is on the display then press SET again And with the keys + and - we change the program 00H or 00C Pressing SET again exits from 0P0 Use the + and - keys to select the next program. From P0 "0P0" to P6 "0P6" P0 program for heating or cooling H/C P1 program in which we set the inertia temperature (higher in the case of set heating, less for the program cooling) after which the regulator is to switch off the heating or cooling. Range between switch-on (set) and off (0.1 to 15C) Example: If the main heating temperature H is set to 24.0C and program P1 is set to 0.7, the regulator switches on at 24.0C and switches off at 24.7C. If the cooling program C is set, the regulator switches off the contact at 23.3C P2 program in which we set the upper temperature limit from -4.5 to 110C P3 program in which we set the lower temperature limit from -50 to 105C P4 program in which we adjust the thermometer in the range from -7 to 7C Set when the display temperature is different from ambient temperature (compare with other thermometers). P5 delay time 0-10 min P6 temperature alarm ON, OFF range 0 to 110C RESET SETTINGS: Press + and - for a few seconds Example of switching on and off the gas furnace (including relay contacts) - heating H - minimum temperature 21C - maximum temperature 22C - temperature alarm 25.0C Press SET, flashes the display with the set temperature, changes the setting to 21.0C Press SET and hold down for 4 seconds, the display will show 0P0, press SET again and set 00H, press SET and display 0P1, SET set to 1.1.0, ie turn off the stove if temp is 1C higher than desired, The stove will turn off at 22.0C P2. set example 027 P3. set example 019 P4. set example 000 P5. set example, 000 P6. For example, ON0 and025Ctemperature alarm on the display will appear dashes Package included: 1 x W1218 Thermostat
   Price history chart & currency exchange rate

Customers also viewed