Multi-function Volt-ammeter 1.8 inch LCD Display Voltage Current Instrument with Power Off Memory Function

Multi-function Volt-ammeter 1.8 inch LCD Display Voltage Current Instrument with Power Off Memory Function
thumb
thumb
thumb
thumb
thumb
TOMTOP
sku: E13751-200
€ 31.30
Shipping from: China
   Description
Features:
Bidirectional current detection, for detecting charge and discharge users can easily detect bidirectional current properties, no need to change the direction of the connection.
Power off power memory function, after power off, the number of AH and WH before power off can be memorized, convenient for observation and measurement.
Time and AH data clearing function, do not affect the measurement later.
The percentage of AH can be set without affecting direct discharge measurement.
Voltage, current, AH, WH, time, power, simultaneously displayed, comprehensive and clear information display.
With output disconnect function key, flexible on or off output.
With over-voltage, over-current, over-temperature and other extended-protection functions.
It can be calibrated online, enabling customers to promptly correct the error.
In the liquid crystal display can be closed when necessary, reduce power consumption.
Function Introduction:
1. BAT battery capacity value setting, this parameter is to set the battery measured total capacity.
2. BPC battery remaining capacity percentage, can be set according to the value of the remaining battery AH.
3. OVP set over-voltage protections value, if the OVP value is set, when the actual measured voltage value is greater than the set value, it will prompt over-voltage, and cut off the relay(self-provisioned).
4. LVP set overvoltage protections value, if you set the LVP value, when the actual measurement of voltage is less than the set value, it will prompt the undervoltage, and cut off the relay(self-provisioned).
5. NCP sets the charge overcurrent protections value. If the NCP value is set, when the actual measured charging-current value is greater than the set value, it will prompt overcurrent and cut off the relay(self-provisioned).
6. OCP sets the discharge overcurrent protections value. If the OCP value is set, when the actual measured discharge current value is greater than the set value, an overcurrent will be prompted and the relay(self-provisioned) will be cut.
7. OTP sets the over-temperature protections value. If the OTP value is set, when the actual measured temperature value is greater than the set value, the over temperature will be prompted and the relay(self-provisioned) will be cut off.
8. ADS communication address code setting.In multi-machine communication, multi-machine communication is achieved by setting the address code.
9. TTL instrument powers up the output state of the default relay, normally open or normally closed.
10. CLR no-load current correction function, if the actual load current is zero.
   Technical Details
categoryName: Test Instruments & Tools > Environmental Measurement Instruments > Other
OriginalPrice: 31.3
product_availability: in stock
Warehouse: CN
   Price history chart & currency exchange rate

Customers also viewed