Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s

Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
hantek
артикул: 1013032
ЗГІДНО З НАШИМИ ДАНИМИ, ЦЕЙ ПРОДУКТ ЗАРАЗ НЕ ДОСТУПНИЙ
$224.99
Доставка з: Китай
   Опис

Description: Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s Features: 100MHz bandwidths 1GSa/s Real Time sample rate Large (7.0-inch) color display,WVGA(800x480) R'ecord length up to 40'K Trigger mode: edge/pulse width/line selectable video/slop/overtime etc. USB host and device connectivity, standard Multiple automatic measurements Four math functions, including FFTs standard Provides software for PC real-time analysis Specification: Model DSO5202P DSO5102P DSO5072P Acquisition Sample Rate Real-Time Sample: 1GS/s Equivalent Sample: 25GS/s Acquisition Modes Normal Normal data only Pea'k Detect High-frequency and randon glith capture Average Wavefom Average, selectable 4,8,16,32,64,128 Inputs Inputs Coupling AC, DC, GND Inpits Impendance 1M2% II20pF3pF Probe Attenuation 1X, 10X Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X Maximum Input Voltage CAT I and CAT II: 300VRMS (10) Installation Category; CAT III: 150VRMS (1); Installation Category II: derate at 20dB/decade above 100kHz to 13V Pea'k AC at 3MHz* and above. For non-sinusoidal waveforms, Pea'k value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur. Horizontal Sample Rate Range 500MS/s--1GS/s Waveform Interpolation (sin x)/x R'ecord Length 40'K SEC/DIV Range 4ns/div to 40s/div 4ns/div to 40s/div Sample Rate and Delay Time Accuracy 50ppm(at over any 1ms time interval) Position Range 2ns/div to 10ns/div; (-4div x s/div) to 20ms; 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s Delta Time Measurement Accuracy (Full Bandwidth) Single-shot, Normal mode: (1 sample interval +100ppm reading + 0.6ns); >16 averages: (1 sample interval + 100ppm reading + 0.4ns); Sample interval = s/div 200 Vertical Vertical Resolution 8-bit resolution, all channel sampled simultaneously Position Range 2mV/div to 200mV/div, 2V 200mV/div to 5V/div, 50V Bandwidth 100MHz 100MHz 70MHz Rise Time at BNC( typical) 3.5ns 3.5ns 5ns Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled 2mV/div to 20mV/div, 400mV; 50mV/div to 200mV/div, 2V 500mV/div to 2V/div, 40V; 5V/div, 50V Math + - * / FFT FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point Bandwidth Limit 20MHz Low Frequency Response (-3db) 10Hz at BNC DC Gain Accuracy 3% for Normal or Average acquisition mode, 5V/div to 10mV/div; 4% for Normal or Average acquisition mode, 5mV/div to 2mV/div DC Measurement Accuracy, Average Acquisition Mode When vertical displacement is zero, and N 16: (3% reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N16: [3% (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div Volts Measurement Repeatability, Average Acquisition Mode Delta volts between any two averages of 16 waveforms acquired under same setup and ambient conditions Trigger System Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative Trigger Source CH1, CH2, EXT, EXT/5, AC Line Trigger Modes Auto, Normal, Single Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject Trigger Sensitivity (Edge Trigger Type) DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz Trigger Level Range CH1/CH2: 8 divisions from center of screen; EXT: 1.2V; EXT/5:6V Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times 20ns CH1/CH2: 0.2div volts/div within 4 divisions from center of screen; EXT: (6% of setting + 40mV); EXT/5: (6% of setting + 200mV); Set Level to 50%(typical) Operates with input signals 50Hz Video Trigger Video Trigger Type CH1, CH2: Pea'k-to-Pea'k amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line Holdoff Range 100ns ~ 10s Pulse Width Trigger Pulse Width Trigger Mode Trigger when ( = or ); Positive pulse or Negative pulse Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width Pulse Width Range 20ns ~ 10s Slope Trigger Slope Trigger Mode Trigger when ( = or ); Positive slope or Negative slope Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. Time Range 20ns ~ 10s Overtime Trigger Over Time Mode Rising edge or Falling edge Time Range 20ns ~ 10s Alternative Trigger Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope Trigger Frequency Counter Readout Resolution 6 digits Accuracy (typical) 30ppm (including all frequency reference errors and 1 count errors) Frequency Range AC coupled, from 4Hz Min to rated bandwidth Signal Source Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to >> Details pictures:

   Графік зміни ціни & курс обміну валют

Користувачі також переглядали