9Pcs MQ2 MQ-3 MQ-4 MQ-5 MQ-6 MQ-7 MQ-8 MQ-9 MQ-135 Gas Sensor Module For Arduino

9Pcs MQ2 MQ-3 MQ-4 MQ-5 MQ-6 MQ-7 MQ-8 MQ-9 MQ-135 Sensor Module For Arduino We will default sending carton package to replace the plastic box, but there may some stocks are still packaging with plastic box, please note about this before you buy it. Feature: MQ-2: Detection concentration: 300-1000ppm(combustible gas). MQ-3: Used in motor vehicles and other no drunken drivers homework personnel on-site testing, also used in other places of ethanol vapor detection. Feature: Size: 32 x 22 x 27mm Main chip: LM393, ZYMQ - 3 gas sensors Working voltage: DC 5V 1, With a signal output instructions. 2, Two-way signal output (TTL level output and analog output) 3, TTL output signal for low level effectively.(when the low output electric signal lights at ordinary times, can be directly by single chip microcomputer) 4, Analog 0 - 5V voltage, the higher the concentration, the higher the voltage. 5, To ethanol steam has a high sensitivity and good selectivity. 6, In June and has long service life and reliable stability. 7, Rapid response recovery features. MQ-4: 1, Using high-quality dual-panel design, with power indicator and TTL signal output instructions; 2, With a DO switch signal (TTL) output and AO analog signal output; 3, TTL output valid signal is low. (When the output low signal light can be directly connected microcontroller or relay module) 4, The analog output voltage, the higher the concentration the higher the voltage. 5, Methane, natural gas has better detection sensitivity. 6, There are four screw holes for easy positioning; 7, Product Dimensions: 32 (L) * 20 (W) * 22 (H) 8, With a long service life and reliable stability 9, Rapid response and recovery characteristics Electrical properties: Input voltage: DC5V power (current): 150mA DO output: TTL digital 0 and 1 (0.1 and 5V) AO output :0.1-0 .3 V (relatively clean) the highest concentration of voltage around 4V MQ-5: Suitable for home or industrial on LPG, natural gas, coal gas monitoring devices. Excellent resistance to alcohol, smoke interference. Module Features: 1, Using high-quality dual-panel design, with power indicator and TTL signal output instructions; 2, With a DO switch signal (TTL) output and AO analog signal output; 3, TTL output valid signal is low. (When the output low signal light can be directly connected microcontroller or relay module) 4, The analog output voltage, the higher the concentration the higher the voltage. 5, For gas, natural gas has better detection sensitivity. 6, There are four screw holes for easy positioning; 7, Product Dimensions: 32* 20 * 22 8, With a long service life and reliable stability 9, Rapid response and recovery characteristics Electrical properties: Input voltage: DC5V power (current): 150mA DO output: TTL digital 0 and 1 (0.1 and 5V) AO output :0.1-0 .3 V (relatively clean) the highest concentration of voltage around 4V MQ-6: Suitable for domestic or industrial on LPG (liquefied petroleum gas) butane, propane, LNG (liquefied natural gas) detection devices. Excellent resistance to ethanol vapor, smoke interference. Module Features: 1, Using high-quality dual-panel design, with power indicator and TTL signal output instructions; 2, With a DO switch signal (TTL) output and AO analog signal output; 3, TTL output valid signal is low. (When the output low signal light can be directly connected microcontroller or relay module) 4, 0 ~ 5V analog output voltage, the higher the concentration the higher the voltage. 5, The propane, butane, LPG, LNG has a good detection sensitivity. 6, There are four screw holes for easy positioning; 7, Product Dimensions: 32 (L) * 20 (W) * 22 (H) 8, With a long service life and reliable stability 9, Rapid response and recovery characteristics Electrical properties: Input voltage: DC5V power (current): 150mA DO output: TTL digital 0 and 1 (0.1 and 5V) AO output :0.1-0 .3 V (relatively clean) the highest concentration of voltage around 4V MQ-7: For home, carbon monoxide detection device environment. Suitable for carbon monoxide and gas detection. Module Features: Detection of concentration: 10-1000ppmCO Loop voltage Vc: =5 Standard test conditions: Temperature: 20 degree 2 degree Humidity: 65% 5% RH Standard test circuit: Vc: 5.0V 0.1V Vh:5.0V0.1V Warm up time: More than 48 hours. Connection: Click here to open Package included: 1 x MQ2 1 x MQ-3 1 x MQ-4 1 x MQ-5 1 x MQ-6 1 x MQ-7 1 x MQ-8 1 x MQ-9 1 x MQ-135 1 x 20pcs 20cm male to female jumper cable 1 x 20pcs 20cm female to female jumper cable If you want another model, you can click on the ID Model Gas Detection Item ID MQ2 flammable gas/smoke 1144079 MQ3 alcohol steam 1414301 MQ4 Natural gas/Methane 1377624 MQ5 Liquefied gas/Methane/Coal gas /LPG 1378464 MQ6 Liquefied gas/Isobutane/Propane/LPG 1378477 MQ7 Carbon monoxide 915474 MQ8 hydrogen 1378425 MQ9 Carbon monoxide flammable gas 1378463 MQ131 Ozone Concentration 1183257 MQ135 Ammonia/sulfide/benzene vapor 1378465 A set of MQ 1005800
Customers also viewed















































